FLEX-NET FX-4017-12N

For projects where flexibility is needed, Micom’s FleX-Net FX-4017-12N Fire Alarm Control Panel is a powerful multi-protocol solution.

PRODUCT INQUIRY

Have a question or need more details? Use the button below to contact us.

Product Inquiry

For projects where flexibility is needed, Micom’s FleX-Net™ FX-4017-12N is a powerful multi-protocol solution.

The FleX-Net FX-4017-12N Fire Alarm Control Panel is designed to meet virtually any application of detection, control, notification, and emergency communications. Features such as fire detection & alarm, audio/voice evacuation, BACnet, Boolean logic, networking and graphical workstation support allow this modular solution to accommodate projects from the simplest systems up to the most complex solutions.

• FleX-Net FX-4017-12N Fire Alarm Control Panel supports multiple intelligent protocols:
– MIX-4000 Devices
– Advanced Protocol (AP)
–  Classic Loop Interface Protocol (CLIP)

• Multiple User Interface Options including:
– 80 characters or 960 characters backlit LCD with the user-friendly menu;
– LED displays adders
– Up to 7 remote annunciators per node.

• Multiple languages are supported including English, French, Arabic, Hebrew, Chinese, Japanese, Italian, Spanish, and Portuguese.

The base panel includes:

  • Main Processor Board with built-in Network card interface, Voice Evacuation System Interface, and IP Port for OpenGN Workstation or BMS Integration.
  • Four (4) Style Z/Y (Class A/B) Notification Appliance

Circuits

  • RS485/RS232/Ethernet Communication Ports
  • Software Features:
  • Boolean Logic Engine for complex sequences of Operations
  • Storage and Management for up to three configuration versions for phased commissioning
  • Audio Message Sequencer
  • Built-in BACnet for BMS System Integration
  • Built-in Webserver for Remote Event Notification

Networking Features

The network configuration allows multiple FleX-Net 4000N Series control panels to be connected using supervised Class A/B circuits to expand the available SLCs, input circuits, visual indication zones, programmable notification appliance circuits, relay outputs and monitor points in the application. The network interface module creates a robust peer-to-peer network via a proprietary protocol that ensures network segments operate independently in case of network impairment. The high baud rate of the network allows for multiplexing of control, audio, and telephony communications over a single copper or fiber interface using advanced compression algorithms. Twisted-Pair Copper, Single-Mode Fiber & Multi-Mode Fiber networking is supported.

Fire Alarm Control Features

  • Expandable up to 28 SLC
  • Each SLC current capability is 200mA in standby and 400mA in alarm. SLC Maximum line resistance 40 Ohms and maximum line capacitance 0.47uF
  • Four Style Z/Y (Class A/B) Notification Appliance Circuits rated at 1.7 Amps each with built-in sync protocol
  • Supports both 80 characters and 960 characters backlit LCD displays with a user-friendly menu
  • Menus and Tags in English, French, Arabic*, Chinese*, Russian*, Spanish and Portuguese. (*needs DSPL-2440DS or RAXN-4000LCDG)
  • Tags only: it accepts all languages supported by Windows 10 (requires graphic annunciator)
  • Correlatable Switch Inputs which allows for multifunctional outputs
  • Sub-addressing to optimize the number of devices in each loop
  • Four Alarm Queues with selector switches and LEDs for Alarm, Supervisory, Monitor and Trouble
  • RS-232 output for remote system printer or terminal
  • RS-485 port for system expansion
  • Ethernet port for OpenGN workstation or BACNet interface
  • Two Event History Logs with capacity for 5000 Alarm Events and 5000 General Events
  • The system can be configured without taking the panel off-line
  • Supports three configuration files (current, previous, and next configuration) with “hot swap” support
  • Supports Boolean logic functions
  • Built-in Ethernet port
  • Remote diagnostics via a built-in web server
  • UL listed for Smoke Control (UUKL)

Network Features

  • Up to 63 nodes
  • Up to 28 SLCs
  • Peer-to-peer network communications
  • Fully integrated digital network audio and control over a single pair of copper wire or fiber optic cable (single or multi-mode)
  • Remote diagnostics via a built-in web server and standard Ethernet port in every node
  • Style 4 (Class B) or Style 6 or 7 (Class A) wiring configuration
  • Proprietary ARCnet Network Communications protocol

MGC Protocol Features

For the new or retrofit expansion of existing applications, MGC Protocol, supports up to 240 devices per SLC Supports:

  • Photo, Heat, and Multi-criteria Sensors
  • Optional Built-In Isolation on Sensors
  • Multiple Input and Multiple Output modules

AP Protocol Features

Advanced Protocol (AP) supports up to 318 devices per SLC (159 sensors & 159 modules). Supports:

  • Smoke, Heat and Fire/CO detection
  • 520 Hz sounder base support on both the addressable loop and through the audio/voice evacuation system.
  • CLIP mode devices – address range for sensors S1-S99 – address range for modules M1-M99.
  • Interrupt operation on the input side to speed detection of an event communication back to the panel
  • Group activation on the output to speed up actions on the outputs

   

mircom header logo white bg
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.