Verify Hub RS485 communication with the TX-CX-A-8 panel. Light indicator should be double green flashing, ( indicating communicating with Lockset and controller); If previous is true, then relocate the lockset... read more →
Ensure that the Card Reader has a TX3-IP module board installed on the main access control board; Network connect to the panel; Port forward the associated IP address and Port... read more →
· Verify that the card encryption type is checked off within the configurator access point’s configuration; · Ensure that the board’s signal ground is stable; · Ensure that the DATA0... read more →
Line Noise: Verify that all units have proper RS485 connections and that no stubs are used on the RS485 lines preventing thorough data updates; Verify that all units have proper... read more →
Communication Signal/Noise issue ( see U5 below) for RS485 ; Ensure that Network cabling have proper one-to-one pin assignments as per T568A or T568B pin outs; and Ensure that the... read more →
Controller registries of last update entries are not registering- communication issue. • Verify that you properly connected the RS485 line to each panel units and that no lines are crossed;... read more →