- Tip and Ring Bi-directional signalling is not differential or in-ground current noise issue:
- Install a 0.1 Micro farad capacitor in series to the Tip. Then line test:
- If the signal/noise improves then Line is unbalance. Request Line Card change-out; OR
- Disconnect Tip and Ring from the module. Measure the voltage ( potential) between Tip and Chassis ground. If voltage exceeds 2.0-2.5 volts:
- then run a 10AWG/Stranded cable from the telephone access unit to the communication demarcation point to ensure voltage drops to approximately 0 potential difference; OR
- Install a 0.1 Micro farad capacitor in series to the Tip. Then line test:
Change out the power supply. Ensure the power supply ground is connected to the power ground and not the communication ground.