SMART BUILDING SOLUTION
A Canadian building automation system built on open standards to simplify integration, improve interoperability, and lower total cost of ownership.
SMART BUILDING SOLUTION
A Canadian building automation system built on
open standards to simplify integration, improve interoperability, and lower total cost of ownership.
cULus - Canada & US
BACnet Testing Labs
System Management Studio
Mircom Group of Companies
Est. 1991
WHY OPENBAS
EDUCATION VERTICAL
School board portfolios often span decades of installs, including N2-Open from legacy JCI/Siemens, Modbus from energy meters, and BACnet from newer equipment. OpenBAS speaks all of them natively from a single controller, with no separate integration layer.
You don't have to upgrade all 40 schools in year one. Modular I/O means you buy exactly the controller sizes each application needs, and the system scales as capital budgets allow.
Public-sector bids demand open-protocol, non-proprietary BAS. We support BACnet, Modbus, and N2-Open right out of the box without complex gateways or expensive comm cards. Plus, our BTL-listed hardware ensures your compliance box is checked early at the spec stage.
Warehouses, Arenas, Transit
Warehouses, Arenas, Transit
Warehouses, Arenas, Transit
Warehouses, Arenas, Transit
HARDWARE
FOR INTEGRATORS
// Point Names/Bindings
DEF BO_1 zoneCool
DEF AI_1 zoneTemp
DEF ADF_1 zoneSptMin
DEF ADF_2 zoneSptMax
// Initial Controller Configurations
UI_CONFIGURATION zoneTemp = AI_TYPE_1kNI_C AI_CALIBRATION = 0.0
zoneSptMin = 21 INITIALIZE
zoneSptMax = 22 INITIALIZE
config.com1.protocol = PROTOCOL_BACNET_MSTP
config.com1.baud = BAUD_38400
config.com1.address = 5
// PLC Logic
// Deadband Cooling: zoneCool On when zoneTemp > zoneSptMax
// zoneCool Off when zoneTemp < zoneSptMin
zoneCool = HYSTERESIS zoneSptMin zoneSptMax zoneTemp
Point names, COM port setup, sensor types, PID loops, schedules. It's all in the same script.
Write your script once. Copy, paste, and batch-load it to controllers sequentially, or run simultaneous threads with multiple ETH3s.
Reviewing sequences shouldn't require a decoder ring. OpenBAS MiScript reads like plain English; it's easy to audit, modify, or hand off to the next technician on the job.
Prefer PLC-style programming? The SDS supports a drag'n'drop, ladder logic interface alongside scripting. Choose your preference, or mix both on the same controller.
Real-time token loop stats, per-device reports, missed token counts, and even helpful on non-OpenBAS networks.
Full RTU packet capture tool for deep Modbus troubleshooting without external hardware or software.
Cloudflare Tunnel support in System Design Studio. Troubleshoot from home, no VPN firewall battles.
SOFTWARE
Free
Powered by Niagara
Early Access
Built-In
Currently in Beta: core dashboard features available now. Role-based access, alarms & trend views coming soon.
PRODUCT CATALOG
8 UI
8 BO - 2 AO
2-3X RS485
UP TO 1,200 RUNGS
4 UI
4 Triac · 2 AO
2× RS485 + MP-Bus
UP TO 1,200 RUNGS
4 UI
4 BO · 2 AO
2× RS485
UP TO 1,200 RUNGS
8 BI · 8 AI + CT
1× RS485
UP TO 1,200 RUNGS
4AO
1× RS485
UP TO 1,200 RUNGS
2× RS485
UP TO 1,200 RUNGS
1 UI · 2 Override
12 Latching Relays
1× RS485
Up to 1,200 rungs
4 V · 4 CT
1× RS485
Ethernet + 2× RS485 + SPI
800 rungs
Windows PC
Free
JACE or PC
8 toggles · 8 pots · 4 UI + temp
8 LED (2 AO · 4 BO)
2× RS485 + SPI
Up to 1,200 rungs
GET IN TOUCH